Line 1: |
Line 1: |
| '''Stage Technologies Automation User Generated Handbook''' | | '''Stage Technologies Automation User Generated Handbook''' |
| | |
| | |
| == Hardware ==
| |
| | |
| '''Moving the winches'''
| |
| | |
| When moving the winches ensure that the entire system is powered down. Unplugging the encoder cables with any power running through the system will cause a "drive error" upon power up. If a drive error does occur it can be reset by either querying the drive and enabling reset or enabling "reset drive" via the "devices" function.
| |
| | |
| Be careful of the counterweight lines while moving, they are easily trapped and damaged
| |
| | |
| == Software ==
| |
| | |
| '''Drive Reset'''
| |
| | |
| If the encoder cables has been unplugged for moving a winch the drive must be reset within Chameleon. Either Query the axis via Axis . Query and execute the reset option under diagnostics or call up the "drive in error" from the Devices menue and execute the drive reset from there. NOTE: The axis must be live on a playback for this to work
| |
| | |
| '''Tab Display'''
| |
| | |
| To set and save the Tabular display for specific shows and/ or <u>users</u> ''confirm''
| |
| | |
| *Right Click on the Blank Desktop
| |
| *Select "Add Data Area"
| |
| *Right Click
| |
| *Select "Edit Axis and click "Ok" when done"
| |
| *Right click on desktop again
| |
| *Select "Save Display"
| |