| '''Stage Technologies Automation User Generated Handbook'''
| | [[Category:Stage Automation]] |
|
| |
|
|
| |
|
| == Hardware ==
| | [[Stage Automation Level 1]] |
|
| |
|
| '''Moving the winches'''
| | [[Stage Automation Level 2]] |
|
| |
|
| If the cables need to be unplugged, in most cases they will, make sure that the e-stop is pressed on the MCC cabinet before unplugging and the sequence reversed after the motors are in position. This makes the drive reset function within Chameleon much simpler.
| | [[Setting Initial Limits on the Winch]] |
|
| |
|
| Be careful of the counterweight lines while moving, they are easily trapped and damaged
| | [[eChameleon]] |
|
| |
|
| == Software ==
| | [[Automated Trucks 2013]] |
|
| |
|
| '''Drive Reset'''
| | [[Automation Class 2014]] |
|
| |
|
| If the encoder cables has been unplugged for moving a winch the drive must be reset within Chameleon. Either Query the axis via Axis . Query and execute the reset option under diagnostics or call up the "drive in error" from the Devices menue and execute the drive reset from there. NOTE: The axis must be live on a playback for this to work
| | [[Control Cabinet Reference]] |
|
| |
|
| '''Tab Display'''
| | [[Big Tow 200 Winches]] |
|
| |
|
| To set and save the Tabular display for specific shows and/ or <u>users</u> ''confirm''
| | [[iQ]] |
| | |
| *Right Click on the Blank Desktop
| |
| *Select "Add Data Area"
| |
| *Right Click
| |
| *Select "Edit Axis and click "Ok" when done"
| |
| *Right click on desktop again
| |
| *Select "Save Display"
| |